User:Shadesofgrey

From Camera-wiki.org
Revision as of 15:37, 11 October 2006 by Shadesofgrey (talk | contribs)
Jump to: navigation, search

I like cameras. I like using them. I like learning about the technical details. I like repairing and modifying cameras.

Camera interests

Cameras:

Interests:

Works in progress

References needed: While most series size filters had plain metal mounts. Towards the end of the era of series filters several manufacturers started making screw-in series filters that didn't require a retaining ring or hood to hold them in place. If these are used with some lenses the original hood may not fit. (reference needed.)

Mercury cells came in number of different sizes including the 625 size (i.e. PX13, EPX625, RPX625, KX625, HD625, PN625, RM625, 4625, H1560, H-D, MR9 and the like), the 675 size (i.e. EPX675, HD675, KX675, RPX675, MR44, H-C and the like), the 400 size (i.e. E400N, EPX400, KX400, PM400R, PX400, RM400, T400N, V400PX and the like), and others. By far the 625 size is the most common.

The following cameras where designed for and require a 625 mercury cell:

Manufacturer Model
Agfa Optima 500 Sensor, Selectronic, Selectronic S, Agfamatic 300/4000/4008/5008/6008, Optima 535/1035/5000/5008/6000/6008
Alpa 9d
Argus 270 Insta-Load
Bell & Howell FD35, Autoload 340/341, Auto Reflex Dial 35
Bronica C2, S2
Canon FT, FTb, FTbn, FT-QL, TX, TLb, EF, F1 (some), Ex, EX EE Auto, A35F, Demi 17, Demi EE 17, Canonet QL17/QL19/19E/25/19E, Canonet New QL17/New QL17L/New QL19/New 28/G-III 17/G-III 19
Chinon SLR, 1000EL pocket, CS, CXII
Dacora Rapid D101, D202, D404
Edixa LTL, 35MM, Prismat, Amica Auto,TL 1000
Exakta TL1000, RTL1000, Examat & Travemat meter finders
Fuji/Fujica 35FS, 35GP, V2
GAF Corporation L-14, L-17, L-CM, L-CS, Anscomatic 726, Autoset Cds
GAF Bernard Auto 35, Model 503, Viceroy 5000
Hanimex 35EE, 35SL, 120, 620, Compact A
Hasselblad Meter Prism Finder CdS
Kalimar K650, K431 Cds meter, K433 zone meter, Zanit 2000CTL
Keiv 60 TTL (2 each)
Keystone K609H, K610H, K616D, K164H, K615H, K1010 Auto
Kodak Retina IIF
Konica AutoReflex T4/TC/Autorex, Auto S/S1.6/S2/S261 meter, EE-Matic, EE-Matic Deluxe F/FM
Kowa SE, SER, SET, SETR, SETR2, 6, 6 MM, Super 66
Leica CL, M5, Leicaflex SL/SL2/SL-MOT/SL2-MOT
Minolta SRT 100/101/200/201/202, SR 1/7/7V/100/102/200/201/202, AL-F, AL-E, Autopack 700, Himatic 7/7s/9/11
Minox 110S
Miranda Sensorex, Automex II/III, F, FM
Nikon F, FTn, FT, T, Tn, Nikkormat FT/FTn/FT2
Olympus 35 series: 35DC/35LC/35RC/35RD/35SC/35SP/35SPN/35UC, EED, FTL, Pen FT
J.C. Penny SLR2/SLR3
Petri FT, FTIII, F1X, Racer, Petriflex 7
Praktica TL, TL1000, Super TL/TL2/TL3, LTL, LTL3, MTL3, Praktica 66 meter, Prakticamat
Ricoh Simplex, Simplex II, SLX 500, TLS 400/EE
Rollei 35, 35S, 35T, 35 Classic, A26, 126, SL35, SL35M, XF35, Rolleiflex SL26
Spiratone Spiraflex TTL
Topcon RE Super, Super DM, 135EE
Vivitar 35EE, 35EF, 35ES
Voitl\"{a}nder VF101, VS1
Yashica MAT 124, MAT 124G, Y12, Y24, Half 14, Lynx 14/14E/5000, Ministar 700D, Penta J3/J4/J5/J7
Zeiss Contaflex 126/SLF, Contarex Super/Super BC, Icarex 35S/35CS/SL706

The following exposure meters where designed for and require a 625 mercury cell:

Manufacturer Model
Aetna/Maxwell D1, D3, L1
Bewi Super L
Bolex Exposure meter for H8/H16 reflex/non-reflex models
Capitol D1, D3, L1
Dot Line DL0016, DL0017
Gossen Super Pilot Cds/SBC, Luna Pro Cds, Luna Six-3 (2 each), C-Mate Cds, N-100
Horseman 4x5 film-plane meter (4 each)
Leica MR3, MR4
Minolta Flash Meter, Color Meter (5 each)
Miranda External Meters F/G, Cadius II, TTP clip-on
Pentax Clip-On Meter
Prinz 160-117 DX-1
Sectra TriColor meter
Sekonic 164A, 164B, 164C
Soligor UF II, Selector Cds
Vivitar 34

To do list