Difference between revisions of "User:Shadesofgrey"

From Camera-wiki.org
Jump to: navigation, search
(List of 625 cell cameras started.)
Line 18: Line 18:
 
* Article on [[Series Filters]]
 
* Article on [[Series Filters]]
  
References needed.  
+
References needed: While most series size filters had plain metal mounts. Towards the end of the era of series filters several manufacturers started making screw-in series filters that didn't require a retaining ring or hood to hold them in place. If these are used with some lenses the original hood may not fit. (reference needed.)
  
While most series size filters had plain metal mounts. Towards the end of the era of series filters several manufacturers started making screw-in series filters that didn't require a retaining ring or hood to hold them in place. If these are used with some lenses the original hood may not fit. (reference needed.)
+
* Article on [[PX625]]
  
The diameter of the filter for each series is:
+
Mercury cells came in number of different sizes including the
 +
625 size (i.e. PX13, EPX625, RPX625,  KX625, HD625, PN625, RM625,
 +
4625, H1560, H-D, MR9 and the like), the 675 size (i.e. EPX675, HD675, KX675,
 +
RPX675, MR44, H-C  and the like), the 400 size (i.e.  E400N, EPX400, KX400,
 +
PM400R, PX400, RM400, T400N, V400PX  and the like), and others. By far the [[PX625 | 625]] size is the most common.
 +
 
 +
The following cameras where designed for and require a 625 mercury cell:
 
:{|  
 
:{|  
|  ||  Series || Diameter (mm)
+
|  ||  Manufacturer || Model
 
|-  
 
|-  
|  ||  IV || 20.6
+
|  ||  [[Agfa]] || Optima 500 Sensor, Selectronic, Selectronic S, Agfamatic 300/4000/4008/5008/6008, Optima 535/1035/5000/5008/6000/6008
 
|-  
 
|-  
|  ||  4.5 || 25.5
+
|  ||  [[Alpa]]  || [[Alpha_9d|9d]]
 
|-  
 
|-  
|  ||  V || 30.2
+
|  ||  [[Argus]] || 270 Insta-Load
 
|-
 
|-
|  ||  5.5 || 35.9
+
|  ||  Bell & Howell || FD35, Autoload 340/341, Auto Reflex Dial 35  
 
|-  
 
|-  
|  ||  VI || 41.3
+
|  ||  [[Bronica]] || C2, S2
|-  
+
|-
|  ||  VII || 50.8
+
|  ||  [[Canon]]  || FT, FTb, FTbn, FT-QL, TX, TLb, EF, F1 (some), Ex, EX EE Auto, A35F, Demi 17, Demi EE 17, Canonet QL17/QL19/19E/25/19E, Canonet New QL17/New QL17L/New QL19/New 28/G-III 17/G-III 19
 +
|-
 +
|  ||  Chinon  || SLR, 1000EL pocket, CS, CXII
 +
|-
 +
|  ||  Dacora  || Rapid D101, D202, D404
 
|-
 
|-
|  ||  7.5 || 57.0
+
|  ||  Edixa  || LTL, 35MM, Prismat, Amica Auto,TL 1000
 
|-
 
|-
|  ||  VIII || 63.5
+
|  ||  [[Exakta]]  || TL1000, RTL1000, Examat & Travemat meter finders
 
|-
 
|-
|  ||  IX || 82.6
+
|  ||  Fuji/Fujica || 35FS, 35GP, V2
 
|-
 
|-
 
|}
 
|}
 +
  
  

Revision as of 05:58, 11 October 2006

I like cameras. I like using them. I like learning about the technical details. I like repairing and modifying cameras.

Camera interests

Cameras:

Interests:

Works in progress

References needed: While most series size filters had plain metal mounts. Towards the end of the era of series filters several manufacturers started making screw-in series filters that didn't require a retaining ring or hood to hold them in place. If these are used with some lenses the original hood may not fit. (reference needed.)

Mercury cells came in number of different sizes including the 625 size (i.e. PX13, EPX625, RPX625, KX625, HD625, PN625, RM625, 4625, H1560, H-D, MR9 and the like), the 675 size (i.e. EPX675, HD675, KX675, RPX675, MR44, H-C and the like), the 400 size (i.e. E400N, EPX400, KX400, PM400R, PX400, RM400, T400N, V400PX and the like), and others. By far the 625 size is the most common.

The following cameras where designed for and require a 625 mercury cell:

Manufacturer Model
Agfa Optima 500 Sensor, Selectronic, Selectronic S, Agfamatic 300/4000/4008/5008/6008, Optima 535/1035/5000/5008/6000/6008
Alpa 9d
Argus 270 Insta-Load
Bell & Howell FD35, Autoload 340/341, Auto Reflex Dial 35
Bronica C2, S2
Canon FT, FTb, FTbn, FT-QL, TX, TLb, EF, F1 (some), Ex, EX EE Auto, A35F, Demi 17, Demi EE 17, Canonet QL17/QL19/19E/25/19E, Canonet New QL17/New QL17L/New QL19/New 28/G-III 17/G-III 19
Chinon SLR, 1000EL pocket, CS, CXII
Dacora Rapid D101, D202, D404
Edixa LTL, 35MM, Prismat, Amica Auto,TL 1000
Exakta TL1000, RTL1000, Examat & Travemat meter finders
Fuji/Fujica 35FS, 35GP, V2


To do list