Difference between revisions of "Gossen Spot-Master"

From Camera-wiki.org
Jump to: navigation, search
(Remove Mavo-Spot, which is an illuminance meter)
m (Links: Repaired Link URL)
 
(5 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Flickr_image
+
{{Infobox_Light_Meter
|image_source= http://www.flickr.com/photos/rst90274/6048395817/in/pool-camerawiki
+
|meter name=Gossen Spot-Master
 +
|image source= http://www.flickr.com/photos/rst90274/6048395817/in/pool-camerawiki
 
|image= http://farm7.static.flickr.com/6084/6048395817_c024f51ac7.jpg
 
|image= http://farm7.static.flickr.com/6084/6048395817_c024f51ac7.jpg
|image_align= right
+
|image caption=Image by {{image_author|rst12}} {{with permission}}
|image_text= Ultra-Spot with case
+
|maker=[[Gossen]]
|image_by= rst12
+
|dates=1988-2000
|image_rights= wp
+
|variants=Spot-Master, Spot-Master 2
 +
|type=Spot exposure meter
 +
|display=[[LCD]] digital in viewfinder
 +
|sensor=SbC (silicon blue diode)
 +
|measurement angle=1° in 15° viewfinder
 +
|multiple measurements=zone system and flash
 +
|ambient sensitivity=1 to 22LV
 +
|flash sensitivity=
 +
|iso range=ISO 1 to 80,000
 +
|incident light=No
 +
|reflected light=Yes
 +
|flash measurement=Yes
 +
|aperture range=f 1 to 190
 +
|time range=1/8,000s to 60 minutes
 +
|battery=9V
 +
|weight=340g
 
}}
 
}}
 +
 
The 1988 [[Gossen]] '''Spot-Master''' (in US '''Ultra-Spot''') is a hand held spot [[exposure meter]]. It has a reflex viewing system with 15° angle of view, within this is marked a 1° circle where light readings are measured by a fast-acting Silicon blue photocell. The display is an LCD readout surrounding the viewing area. Both ambient and flash light can be measured.
 
The 1988 [[Gossen]] '''Spot-Master''' (in US '''Ultra-Spot''') is a hand held spot [[exposure meter]]. It has a reflex viewing system with 15° angle of view, within this is marked a 1° circle where light readings are measured by a fast-acting Silicon blue photocell. The display is an LCD readout surrounding the viewing area. Both ambient and flash light can be measured.
  
 
Measurement modes are: ambient, flash, EV, zone, and cine. When measuring flash the corresponding ambient light setting is also displayed.
 
Measurement modes are: ambient, flash, EV, zone, and cine. When measuring flash the corresponding ambient light setting is also displayed.
  
The meter will average up to 10 ambient readings. It will also store readings according to the zone system, averaging the highest and lowest.
+
The meter will average up to 10 ambient readings. It will also store up to 10 readings according to the zone system, averaging the highest and lowest. Zone readings may be shifted on the scale, and contrast increased or decreased with corresponding development adjustment displayed.
 
 
The 1994 '''Spot-Master 2''' has minor revisions, operation and specifications are identical.
 
 
 
==Speciifications==
 
{| class="wikitable"
 
!|
 
!|Spot-Master
 
!|Spot-Master 2
 
|-
 
!|Type
 
|Colspan=2|Hand held spot exposure meter
 
|-
 
!|Introduction
 
|1988
 
|1994
 
|-
 
!|Sensor
 
|Colspan=2|SBC (Silicon Blue Cell)
 
|-
 
!|Measurement
 
|Colspan=2|Reflected, ambient and flash
 
|-
 
!|Sensitivity
 
|Colspan=2|+1 to +22 EV
 
|-
 
!|Display
 
|Colspan=2|LCD in viewfinder
 
|-
 
!|Film Speed
 
|Colspan=2|ISO/ASA 1 to 80,000
 
|-
 
!|Aperture
 
|Colspan=2|f1 to f128
 
|-
 
!|Time
 
|Colspan=2|1/8,000 to 60 minutes
 
|-
 
!|Power
 
|Colspan=2|9v battery
 
|-
 
!|Memory
 
|Colspan=2|Up to 10 readings averaged
 
|-
 
|-
 
!|Dimensions
 
|Colspan=2|90 x 57 x 190mm
 
|-
 
!|Weight
 
|Colspan=2|340g
 
|}
 
  
 +
The 1994 '''Spot-Master 2''' has minor revisions, operation and specifications are identical apart from increased flash range.
  
==Links-==
+
==Links==
 
*[http://www.butkus.org/chinon/flashes_meters/gossen_ultra-spot/gossen_ultra-spot.htm Gossen Ultra-Spot manual] at Mike Butkus' [http://www.butkus.org/chinon/ OrphanCameras.com]
 
*[http://www.butkus.org/chinon/flashes_meters/gossen_ultra-spot/gossen_ultra-spot.htm Gossen Ultra-Spot manual] at Mike Butkus' [http://www.butkus.org/chinon/ OrphanCameras.com]
 
*[http://www.butkus.org/chinon/flashes_meters/gossen_ultra_spot_2/gossen_ultra_spot_2.htm Gossen Ultra-Spot 2 manual] at Mike Butkus' [http://www.butkus.org/chinon/ OrphanCameras.com]
 
*[http://www.butkus.org/chinon/flashes_meters/gossen_ultra_spot_2/gossen_ultra_spot_2.htm Gossen Ultra-Spot 2 manual] at Mike Butkus' [http://www.butkus.org/chinon/ OrphanCameras.com]
*[http://www.gossen-photo.de/pdf/ba_spotmaster2_e.pdf Gossen Spot-Master 2 manual] from [http://www.gossen-photo.de/english/index.php Gossen website]
+
*[https://gossen-photo.de/wp-content/uploads/DL/FOTO/AG/ba_spotmaster2_d.pdf Gossen Spot-Master 2 manual (pdf) (in German)] from [http://www.gossen-photo.de/english/index.php Gossen website]
 +
 
 +
[[Category:Meters]]
 +
[[Category:Gossen|Spot-Master]]

Latest revision as of 06:33, 4 October 2022

Gossen Spot-Master

Maker: Gossen

Dates: 1988-2000

Variants: Spot-Master, Spot-Master 2

Type: Spot exposure meter


Display: LCD digital in viewfinder

Sensor: SbC (silicon blue diode)

Measurement angle: 1° in 15° viewfinder

Multiple measurements: zone system and flash

Ambient sensitivity: 1 to 22LV

Flash sensitivity:

ASA/ISO range: ISO 1 to 80,000

Incident light: No

Reflected light: Yes

Flash measurement: Yes

Aperture range: f 1 to 190

Time range: 1/8,000s to 60 minutes

Battery: 9V

Weight: 340g


The 1988 Gossen Spot-Master (in US Ultra-Spot) is a hand held spot exposure meter. It has a reflex viewing system with 15° angle of view, within this is marked a 1° circle where light readings are measured by a fast-acting Silicon blue photocell. The display is an LCD readout surrounding the viewing area. Both ambient and flash light can be measured.

Measurement modes are: ambient, flash, EV, zone, and cine. When measuring flash the corresponding ambient light setting is also displayed.

The meter will average up to 10 ambient readings. It will also store up to 10 readings according to the zone system, averaging the highest and lowest. Zone readings may be shifted on the scale, and contrast increased or decreased with corresponding development adjustment displayed.

The 1994 Spot-Master 2 has minor revisions, operation and specifications are identical apart from increased flash range.

Links