Difference between revisions of "Gossen Spot-Master"
(Additional data) |
(Remove Mavo-Spot, which is an illuminance meter) |
||
Line 13: | Line 13: | ||
The meter will average up to 10 ambient readings. It will also store readings according to the zone system, averaging the highest and lowest. | The meter will average up to 10 ambient readings. It will also store readings according to the zone system, averaging the highest and lowest. | ||
− | The 1994 '''Spot-Master 2''' has minor revisions | + | The 1994 '''Spot-Master 2''' has minor revisions, operation and specifications are identical. |
− | |||
− | |||
==Speciifications== | ==Speciifications== | ||
Line 22: | Line 20: | ||
!|Spot-Master | !|Spot-Master | ||
!|Spot-Master 2 | !|Spot-Master 2 | ||
− | |||
|- | |- | ||
!|Type | !|Type | ||
− | |Colspan= | + | |Colspan=2|Hand held spot exposure meter |
|- | |- | ||
!|Introduction | !|Introduction | ||
|1988 | |1988 | ||
|1994 | |1994 | ||
− | |||
|- | |- | ||
!|Sensor | !|Sensor | ||
− | |Colspan= | + | |Colspan=2|SBC (Silicon Blue Cell) |
|- | |- | ||
!|Measurement | !|Measurement | ||
− | |Colspan= | + | |Colspan=2|Reflected, ambient and flash |
|- | |- | ||
!|Sensitivity | !|Sensitivity | ||
|Colspan=2|+1 to +22 EV | |Colspan=2|+1 to +22 EV | ||
− | |||
|- | |- | ||
!|Display | !|Display | ||
− | |Colspan= | + | |Colspan=2|LCD in viewfinder |
|- | |- | ||
!|Film Speed | !|Film Speed | ||
|Colspan=2|ISO/ASA 1 to 80,000 | |Colspan=2|ISO/ASA 1 to 80,000 | ||
− | |||
|- | |- | ||
!|Aperture | !|Aperture | ||
|Colspan=2|f1 to f128 | |Colspan=2|f1 to f128 | ||
− | |||
|- | |- | ||
!|Time | !|Time | ||
|Colspan=2|1/8,000 to 60 minutes | |Colspan=2|1/8,000 to 60 minutes | ||
− | |||
|- | |- | ||
!|Power | !|Power | ||
|Colspan=2|9v battery | |Colspan=2|9v battery | ||
− | |||
|- | |- | ||
!|Memory | !|Memory | ||
|Colspan=2|Up to 10 readings averaged | |Colspan=2|Up to 10 readings averaged | ||
− | |||
|- | |- | ||
− | |||
− | |||
− | |||
|- | |- | ||
!|Dimensions | !|Dimensions | ||
− | |Colspan= | + | |Colspan=2|90 x 57 x 190mm |
|- | |- | ||
!|Weight | !|Weight | ||
|Colspan=2|340g | |Colspan=2|340g | ||
− | |||
|} | |} | ||
Revision as of 12:16, 28 May 2012
Ultra-Spot with case image by rst12 (Image rights) |
The 1988 Gossen Spot-Master (in US Ultra-Spot) is a hand held spot exposure meter. It has a reflex viewing system with 15° angle of view, within this is marked a 1° circle where light readings are measured by a fast-acting Silicon blue photocell. The display is an LCD readout surrounding the viewing area. Both ambient and flash light can be measured.
Measurement modes are: ambient, flash, EV, zone, and cine. When measuring flash the corresponding ambient light setting is also displayed.
The meter will average up to 10 ambient readings. It will also store readings according to the zone system, averaging the highest and lowest.
The 1994 Spot-Master 2 has minor revisions, operation and specifications are identical.
Speciifications
Spot-Master | Spot-Master 2 | |
---|---|---|
Type | Hand held spot exposure meter | |
Introduction | 1988 | 1994 |
Sensor | SBC (Silicon Blue Cell) | |
Measurement | Reflected, ambient and flash | |
Sensitivity | +1 to +22 EV | |
Display | LCD in viewfinder | |
Film Speed | ISO/ASA 1 to 80,000 | |
Aperture | f1 to f128 | |
Time | 1/8,000 to 60 minutes | |
Power | 9v battery | |
Memory | Up to 10 readings averaged | |
Dimensions | 90 x 57 x 190mm | |
Weight | 340g |
Links-
- Gossen Ultra-Spot manual at Mike Butkus' OrphanCameras.com
- Gossen Ultra-Spot 2 manual at Mike Butkus' OrphanCameras.com
- Gossen Spot-Master 2 manual from Gossen website